ORIGINAL RESEARCH
Effectiveness of Indicatory Microorganisms Removal on Trickling Filter with Biofilm in Magnetic Field
Z. Filipkowska1, M. Krzemieniewski2
 
More details
Hide details
 
Olsztyn University of Agriculture and Technology, Department of Ecology, 1Sanitary Microbiology Unit, 2Department of Chemistry and Water and Wastewater Technology, 10-957 Olsztyn-Kortowo, Poland
 
 
Pol. J. Environ. Stud. 1998;7(4):201-205
 
KEYWORDS
ABSTRACT
The objective of study was to define the removal rate of the indicator microorganisms on various types of trickling filters with regard to the influence of: magnetic stream and electric current passage, on the effectiveness of microorganisms adsorption onto the media. The hydraulic loading in the first eight variants were changing, variants 9-14 were peformed at a constant loading. The study results have indicated a positive influence of the extra energy sources i. e. a magnetic stream and electric current on the process of indicatory microorganisms removal from the waste water.